The ASTM F3561 standard measures time-based resistance by evaluating how long a complete glazing assembly—including the frame, glass, and security film—can deny an attacker physical access under a sustained assault. Unlike earlier standards that relied on static loads, ASTM F3561 uses a dynamic, three-phase sequence to simulate real-world attacks.
The Testing Sequence
The protocol follows a structured progression to test the assembly’s durability:
- Initial Impacts: A calibrated pendulum device delivers a specific number of strikes to weaken the glass, simulating an attacker hitting the surface with a heavy object.
- Tool Application: Immediately following the impacts, technicians apply primary tools (such as screwdrivers, pry bars, or hammers) directly to the damaged area to attempt a breach.
- Timed Resistance window: The resistance is measured in seconds. If a tool fully penetrates the assembly before the time limit for a specific level is reached, the system fails. If it denies penetration for the full duration, it passes.
Performance Levels (1–4)
Resistance is classified into levels based on the duration of the attack and the tools used:
- Level 1: 60 seconds of resistance against a screwdriver and pry bar (5 impacts).
- Level 2: 120 seconds of resistance, adding a hammer to the toolkit (7 impacts).
- Level 3: 180 seconds of resistance, including use of a sledgehammer (10 impacts).
- Level 4: 300 seconds (5 minutes) of resistance against power tools and all lower-level implements (15 impacts).
To achieve higher levels, such as Level 3, security films are typically paired with impact protection attachment systems (like wet glaze or mechanical anchoring) to prevent the entire filmed panel from being pushed out of the frame.
Related FAQs
-
What Documentation is Needed to Justify Security Film for Grant Applications?
Read More »: What Documentation is Needed to Justify Security Film for Grant Applications?To successfully justify the need for security film in grant applications, schools must provide a clear, evidence-based proposal that demonstrates an urgent need and aligns with specific program goals. Key documentation and supporting evidence include: Comprehensive Campus Security Assessments: A…
-
How Many Years does Professional Commercial Security Film Typically Last?
Read More »: How Many Years does Professional Commercial Security Film Typically Last?When investing in commercial window security solutions, professionally installed film typically has a lifespan of 10–15 years under normal conditions. To ensure your security film remains effective for a decade or more, consider the following factors that influence its longevity:…
-
What are the Best Physical Security Upgrades for Retail Storefronts?
Read More »: What are the Best Physical Security Upgrades for Retail Storefronts?For retail storefronts, the most effective physical security upgrades involve high-performance window films that reinforce glass without compromising aesthetics or visibility. Unlike traditional security bars, these solutions are discreet and do not create a restrictive appearance. Key physical security upgrades…
-
How does Security Film Integrate into a Holistic School Safety Plan?
Read More »: How does Security Film Integrate into a Holistic School Safety Plan?In a holistic school safety plan, security window film acts as a critical intruder delay strategy within a layered defense framework. Rather than acting as a standalone solution, it is integrated with electronic systems, physical hardening, and procedural protocols to…
-
What are the Best Practices for Hardening School Entry Points?
Read More »: What are the Best Practices for Hardening School Entry Points?Hardening school entry points involves a layered approach that focuses on the perimeter’s most vulnerable areas, such as doors, windows, and vestibules. According to Amarok Defense, the best practices for strengthening these areas include: Applying security window film: Install high-tensile…