The ASTM F3561 standard measures time-based resistance by evaluating how long a complete glazing assembly—including the frame, glass, and security film—can deny an attacker physical access under a sustained assault. Unlike earlier standards that relied on static loads, ASTM F3561 uses a dynamic, three-phase sequence to simulate real-world attacks.
The Testing Sequence
The protocol follows a structured progression to test the assembly’s durability:
- Initial Impacts: A calibrated pendulum device delivers a specific number of strikes to weaken the glass, simulating an attacker hitting the surface with a heavy object.
- Tool Application: Immediately following the impacts, technicians apply primary tools (such as screwdrivers, pry bars, or hammers) directly to the damaged area to attempt a breach.
- Timed Resistance window: The resistance is measured in seconds. If a tool fully penetrates the assembly before the time limit for a specific level is reached, the system fails. If it denies penetration for the full duration, it passes.
Performance Levels (1–4)
Resistance is classified into levels based on the duration of the attack and the tools used:
- Level 1: 60 seconds of resistance against a screwdriver and pry bar (5 impacts).
- Level 2: 120 seconds of resistance, adding a hammer to the toolkit (7 impacts).
- Level 3: 180 seconds of resistance, including use of a sledgehammer (10 impacts).
- Level 4: 300 seconds (5 minutes) of resistance against power tools and all lower-level implements (15 impacts).
To achieve higher levels, such as Level 3, security films are typically paired with impact protection attachment systems (like wet glaze or mechanical anchoring) to prevent the entire filmed panel from being pushed out of the frame.
Related FAQs
-
Can Ceramic Tint be Combined with Heavy-duty Security Layers?
Read More »: Can Ceramic Tint be Combined with Heavy-duty Security Layers?Yes, ceramic tint can be combined with heavy-duty security layers, but the installation process must follow a specific technical order to ensure both films perform effectively. To achieve the best results, the security film must be applied first, directly onto…
-
How Many Impacts can Astm F3561 Glass Withstand before Penetration?
Read More »: How Many Impacts can Astm F3561 Glass Withstand before Penetration?The number of impacts a glazing assembly can withstand before penetration depends on the specific ASTM F3561 forced entry level being tested. The standard utilizes a structured sequence of initial impacts from a calibrated pendulum device to weaken the glass…
-
Where can I Find Authorized 3m Security Film Dealers in Phoenix?
Read More »: Where can I Find Authorized 3m Security Film Dealers in Phoenix?In the Phoenix and Arizona area, Amarok Defense Company is a specialized provider of 3M security window film. They offer professional installation for commercial and institutional properties with a team that brings over 75 years of combined law enforcement and…
-
What are the Latest Trends in Commercial Building Hardening for 2026?
Read More »: What are the Latest Trends in Commercial Building Hardening for 2026?For 2026, the trends in commercial building hardening are focused on standardized physical protection and the integration of diverse security technologies. According to Amarok Defense, there are three primary trends reshaping the industry: While these trends significantly improve a building’s…
-
What Federal Grants Cover School Security Window Film in 2026?
Read More »: What Federal Grants Cover School Security Window Film in 2026?In 2026, two primary federal grant programs provide funding for the installation of security window film as a physical security enhancement for schools: COPS School Violence Prevention Program (SVPP): This nationwide federal grant explicitly covers physical security hardening, including window…