The U.S. General Services Administration (GSA) uses a classification system to rate security window films based on the GSA-TS-1-2003 test method. This system measures a glazing system’s ability to contain glass fragments and maintain structural integrity when subjected to an external explosive charge at a 50-meter standoff distance.
The four GSA levels of protection are defined as follows:
- Level 1 (Minimum Protection): Tested against 2.3 kg of TNT. The glass may break, but the film retains fragments and prevents perforation of the glazing. This is typically used for low-risk interior partitions.
- Level 2 (Moderate Protection): Tested against 4.5 kg of TNT. The glazing remains in the frame; while some glass breakage is allowed, the film must prevent major fragmentation. Common applications include office buildings and reception areas.
- Level 3 (High Protection): Tested against 9.1 kg of TNT. The glass may break, but the film retains all fragments and no significant opening is formed. This level is used for government facilities, schools, and high-value commercial buildings.
- Level 4 (Very High Protection): Tested against 13.6 kg of TNT. The glazing remains in the frame and the film retains all fragments with very limited structural breach. This is intended for embassies, critical infrastructure, and military facilities.
Note that these levels represent blast mitigation performance, not ballistic protection. Security window film is NOT bullet-resistant.
Related FAQs
-
Which States Currently have Glass Hardening Mandates for Schools?
Read More »: Which States Currently have Glass Hardening Mandates for Schools?Based on current legislative trends and school safety requirements, several states have implemented mandates or significant physical security requirements for glass hardening in schools. These actions are often driven by Alyssa’s Law and related safety acts. According to the provided…
-
What is the Deadline for Schools to Install Security Glazing under New Legislation?
Read More »: What is the Deadline for Schools to Install Security Glazing under New Legislation?Under current legislation and evolving state-level regulations, many school districts are facing a compliance deadline of 2026 for installing security glazing. Key details regarding these deadlines include: 2026 Compliance Timeline: State regulations, specifically those in Florida, have established phased deadlines…
-
What are the Requirements for School Window Reinforcement in 2026?
Read More »: What are the Requirements for School Window Reinforcement in 2026?By 2026, many school districts in the United States must comply with evolving state-level mandates that require reinforcing windows and glass doors against forced entry. These requirements are often phased, with 2026 serving as a critical deadline for new construction…
-
What are the Gsa Levels of Protection for Security Window Films?
Read More »: What are the Gsa Levels of Protection for Security Window Films?The U.S. General Services Administration (GSA) uses a classification system to rate security window films based on the GSA-TS-1-2003 test method. This system measures a glazing system’s ability to contain glass fragments and maintain structural integrity when subjected to an…
-
How does Glass Reinforcement Fit into a 2026 Facility Security Audit?
Read More »: How does Glass Reinforcement Fit into a 2026 Facility Security Audit?In the context of a 2026 facility security audit, glass reinforcement serves as a documented and verifiable physical hardening measure. Audit requirements for 2026 are increasingly emphasizing physical hardening as a core compliance criterion. Integrating glass reinforcement into your audit…