The ASTM F3561 standard measures time-based resistance by evaluating how long a complete glazing assembly—including the frame, glass, and security film—can deny an attacker physical access under a sustained assault. Unlike earlier standards that relied on static loads, ASTM F3561 uses a dynamic, three-phase sequence to simulate real-world attacks.
The Testing Sequence
The protocol follows a structured progression to test the assembly’s durability:
- Initial Impacts: A calibrated pendulum device delivers a specific number of strikes to weaken the glass, simulating an attacker hitting the surface with a heavy object.
- Tool Application: Immediately following the impacts, technicians apply primary tools (such as screwdrivers, pry bars, or hammers) directly to the damaged area to attempt a breach.
- Timed Resistance window: The resistance is measured in seconds. If a tool fully penetrates the assembly before the time limit for a specific level is reached, the system fails. If it denies penetration for the full duration, it passes.
Performance Levels (1–4)
Resistance is classified into levels based on the duration of the attack and the tools used:
- Level 1: 60 seconds of resistance against a screwdriver and pry bar (5 impacts).
- Level 2: 120 seconds of resistance, adding a hammer to the toolkit (7 impacts).
- Level 3: 180 seconds of resistance, including use of a sledgehammer (10 impacts).
- Level 4: 300 seconds (5 minutes) of resistance against power tools and all lower-level implements (15 impacts).
To achieve higher levels, such as Level 3, security films are typically paired with impact protection attachment systems (like wet glaze or mechanical anchoring) to prevent the entire filmed panel from being pushed out of the frame.
Related FAQs
-
Which States Currently have Glass Hardening Mandates for Schools?
Read More »: Which States Currently have Glass Hardening Mandates for Schools?Based on current legislative trends and school safety requirements, several states have implemented mandates or significant physical security requirements for glass hardening in schools. These actions are often driven by Alyssa’s Law and related safety acts. According to the provided…
-
What is the Deadline for Schools to Install Security Glazing under New Legislation?
Read More »: What is the Deadline for Schools to Install Security Glazing under New Legislation?Under current legislation and evolving state-level regulations, many school districts are facing a compliance deadline of 2026 for installing security glazing. Key details regarding these deadlines include: 2026 Compliance Timeline: State regulations, specifically those in Florida, have established phased deadlines…
-
What are the Requirements for School Window Reinforcement in 2026?
Read More »: What are the Requirements for School Window Reinforcement in 2026?By 2026, many school districts in the United States must comply with evolving state-level mandates that require reinforcing windows and glass doors against forced entry. These requirements are often phased, with 2026 serving as a critical deadline for new construction…
-
What are the Gsa Levels of Protection for Security Window Films?
Read More »: What are the Gsa Levels of Protection for Security Window Films?The U.S. General Services Administration (GSA) uses a classification system to rate security window films based on the GSA-TS-1-2003 test method. This system measures a glazing system’s ability to contain glass fragments and maintain structural integrity when subjected to an…
-
How does Glass Reinforcement Fit into a 2026 Facility Security Audit?
Read More »: How does Glass Reinforcement Fit into a 2026 Facility Security Audit?In the context of a 2026 facility security audit, glass reinforcement serves as a documented and verifiable physical hardening measure. Audit requirements for 2026 are increasingly emphasizing physical hardening as a core compliance criterion. Integrating glass reinforcement into your audit…